Liver stiffness by US.transient elastography   77615-3

LOINC Code


LOINC code77615-3
nameLiver stiffness by US.transient elastography
descriptionLiver stiffness is measured in a non-invasive manner by vibration-controlled transient elastography (VCTE). VCTE uses an ultrasound transducer mounted on the axis of a mechanical vibrator. The vibrator induces a 50 Hz shear wave through the liver and ultrasounds are used to track the propagation of the shear wave and measure its speed of propagation into the liver. The speed is converted into stiffness using Hooke's law. Stiffness measurements are expressed in kPa. Clinical interpretation of liver stiffness values should always be in the hands of an expert clinician and should be made with full knowledge of patient demographics, disease etiology and essential laboratory parameters.
statusACTIVE

Fully-Specified Name

componentLiver stiffness
propertyPres  =  Pressure
timePt  =  Point in time:  To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements.
systemAbdomen>Liver
scaleQn  =  Quantitative:  The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256
methodUS.transient elastography

Additional Names

short nameUS.TE Liver stiffness

Basic Attributes

classRAD
type2  Clinical
order vs. observationBoth
example UCUM unitskPa
The Unified Code for Units of Measure (UCUM) is a code system intended to include all units of measures being contemporarily used in international science, engineering, and business (www.unitsofmeasure.org)
example unitkpa

Associated Observations

LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations.

Member of these Groups

LG41823-2Region imaged: Abdomen

History/Usage

test rank9609 of 2000 most commonly performed tests by labs in USA
first released
last updated2.73
last change typeMIN  - change to field other than name
change reasonChanged System from "Liver" for conformance with the LOINC/RadLex unified model.

Related Names

Abd
Abdo
Abdomen+
Abdominal
Echography
Fibroscan
Hepar
Hepatic
Imaging
Point in time
Pressure
QNT
Quan
Quant
Quantitative
RADIOLOGY
Random
Sonogram
Sonograph
Sonography
ULS
Ultrasound
US.TE

Copyright © 2023 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2023, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.

demo
request yours today
subscribe
start today
newsletter
free subscription

Thank you for choosing Find-A-Code, please Sign In to remove ads.