Isotopic Glomerular filtration rate/1.73 sq M [Volume Rate/Area] in Urine and Serum or Plasma   78006-4

LOINC Code


LOINC code78006-4
nameIsotopic Glomerular filtration rate/1.73 sq M [Volume Rate/Area] in Urine and Serum or Plasma
descriptionThis test measures kidney filtration after injection of a radioactive tracer (e.g. technetium 99m DTPA). It is an actual measurement of glomerular filtration rate (GFR). The test is a several hour long kidney function test typically performed to accurately verify the level of renal dysfunction. It requires sequential collection of both blood and urine specimens after the tracer injection. Isotopic GFR may be used for monitoring renal function over time, or in chronic renal failure patients approaching dialysis. [PMID: 1391702] The submitter's lab uses the following formula to determine GFR: GFR = (UV/P) x (1.73/BSA) Where, for each timed urine collection, U = (urine collection CPM = UbkgCPM) V = urine flow rate: (urine volume / elapsed time) in units of mL/min P = (average serum or plasma CPM = Bbkg CPM) The average serum CPM (counts per minute) will be the average of Bo and B1 for the first urine collection (U1) and the average of B1 and B2 for the second collection (U2). Average the calculated GFR results for the two collection periods to obtain the final GFR result.
statusACTIVE

Fully-Specified Name

componentGlomerular filtration rate/1.73 sq M
propertyArVRat  =  Volume Rate/Area
timePt  =  Point in time:  To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements.
systemUrine+Ser/Plas
    Ser  =  Serum
    Plas  =  Plasma
scaleQn  =  Quantitative:  The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256
methodIsotopic

Additional Names

short nameIsotopic GFR/1.73 sq M Ur+SerPl-ArVRat

Basic Attributes

classCHEM
type1  Laboratory
order vs. observationBoth
example UCUM unitsmL/min/{1.73_m2}
The Unified Code for Units of Measure (UCUM) is a code system intended to include all units of measures being contemporarily used in international science, engineering, and business (www.unitsofmeasure.org)
example unitmL/min/1.73 sq m

Associated Observations

LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations.

History/Usage

first released
last updated2.72
last change typeMIN  - change to field other than name
change reasonRelease 2.72: FORMULA: Formula removed from visible LOINC field due to complexity.;

Related Names

BSA
Chemistry
GFR
GFR/1.73 sq M
Glom
Kidney
Nephrology
Pl
Plasma
Plsm
Point in time
QNT
Quan
Quant
Quantitative
Random
Renal
SerP
SerPl
SerPlas
Serum
Serum or plasma
Square Meter
SR
UA
UR
Ur+SerPl
Urn
Volume rate/area
Volume Rate/Ratio

Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.