Influenza virus B Yamagata lineage RNA [Cycle Threshold #] in Respiratory system specimen by NAA with probe detection   81325-3

LOINC Code


LOINC code81325-3
nameInfluenza virus B Yamagata lineage RNA [Cycle Threshold #] in Respiratory system specimen by NAA with probe detection
statusACTIVE

Fully-Specified Name

componentInfluenza virus B Yamagata lineage RNA
    B  =  Buccal
propertyThreshNum  =  Threshold Number
timePt  =  Point in time:  To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements.
systemRespiratory System Specimen
scaleQn  =  Quantitative:  The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256
methodProbe.amp.tar

Additional Names

short nameFLUBV Yam RNA Ct Resp Qn NAA+probe

Basic Attributes

classMICRO
type1  Laboratory
order vs. observationBoth
example UCUM units{Ct_value}
The Unified Code for Units of Measure (UCUM) is a code system intended to include all units of measures being contemporarily used in international science, engineering, and business (www.unitsofmeasure.org)
example unitCt

Associated Observations

LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations.

Member of these Groups

LG32757-3Influenza virus

Member of these Panels

81233-9Influenza virus types A and B and subtypes RNA panel - Respiratory system specimen by NAA with probe detection

History/Usage

first released
last updated2.75
last change typeMAJ  - change to name field other than Component;
change reasonRelease 2.75: SYSTEM: There are 2 similar system's in LOINC: 1- Respiratory system 2- Respiratory specimen Due to an applied logic, the display in the System axis for 1 is Respiratory (adjective) without specification of sample, specimen, or other specific noun, while 2 is displayed fully as Respiratory specimen. Therefore for now we replaced 1 with Respiratory system specimen, which will affect 83 term. The result is replacing "Respiratory" with "Respiratory system specimen". This is the short approach. The bigger project is to potentially merge data that has either 1 or 2 together. This is a project to pass by the laboratory committee and will involve about 1500 concepts.;

Related Names

3 Self-Sustaining Sequence Replication
3SR SR
Amplif
Amplification
Amplified
Breathing
DNA NUCLEIC ACID PROBE
DNA probe
FLUB
FLUBV
FLUBV Yam
FLUV
ID
Infectious Disease
InfectiousDisease
Influ
Influenza B
Influenza B virus
LAT
LCR
Ligase chain reaction
Ligation-activated transcription
Lung
Lungs
Microbiology
NAA+probe
NAAT
NASBA
Nucleic acid sequence based analysis
PCR
PH
Point in time
Polymerase chain reaction
Probe amp
Probe with ampification
Probe with target amplification
Public Health
PublicHealth
Pulmonary
Pulmonology
QBR
QNT
Quan
Quant
Quantitative
Random
Respiratory
Ribonucleic acid
RS
SDA
Spec
Strand Displacement Amplification
TMA
Transcription mediated amplification

Copyright © 2023 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2023, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.

demo
request yours today
subscribe
start today
newsletter
free subscription

Thank you for choosing Find-A-Code, please Sign In to remove ads.