Human RNase P RNA [Cycle Threshold #] in Respiratory system specimen by NAA with probe detection   81326-1

LOINC Code


LOINC code81326-1
nameHuman RNase P RNA [Cycle Threshold #] in Respiratory system specimen by NAA with probe detection
descriptionHuman RNase P is used as an internal control with human clinical specimens to confirm that nucleic acid was adequately extracted from. Possible specimens include: upper respiratory tract clinical specimens (including nasopharyngeal swabs, nasal swabs, throat swabs, nasal aspirates, nasal washes, and dual nasopharyngeal/throat swabs), and lower respiratory tract specimens (including bronchoalveolar lavage, bronchial wash, tracheal aspirate, sputum, and lung tissue.
statusACTIVE

Fully-Specified Name

componentHuman RNase P RNA
propertyThreshNum  =  Threshold Number
timePt  =  Point in time:  To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements.
systemRespiratory System Specimen
scaleQn  =  Quantitative:  The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256
methodProbe.amp.tar

Additional Names

short nameHuman RNase P RNA Ct Resp Qn NAA+probe

Basic Attributes

classMICRO
type1  Laboratory
order vs. observationBoth
example UCUM units{Ct_value}
The Unified Code for Units of Measure (UCUM) is a code system intended to include all units of measures being contemporarily used in international science, engineering, and business (www.unitsofmeasure.org)
example unitCt

Associated Observations

LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations.

Member of these Panels

81233-9Influenza virus types A and B and subtypes RNA panel - Respiratory system specimen by NAA with probe detection

History/Usage

first released
last updated2.75
last change typeMAJ  - change to name field other than Component;
change reasonRelease 2.75: SYSTEM: There are 2 similar system's in LOINC: 1- Respiratory system 2- Respiratory specimen Due to an applied logic, the display in the System axis for 1 is Respiratory (adjective) without specification of sample, specimen, or other specific noun, while 2 is displayed fully as Respiratory specimen. Therefore for now we replaced 1 with Respiratory system specimen, which will affect 83 term. The result is replacing "Respiratory" with "Respiratory system specimen". This is the short approach. The bigger project is to potentially merge data that has either 1 or 2 together. This is a project to pass by the laboratory committee and will involve about 1500 concepts.;

Related Names

3 Self-Sustaining Sequence Replication
3SR SR
Amplif
Amplification
Amplified
Breathing
DNA NUCLEIC ACID PROBE
DNA probe
LAT
LCR
Ligase chain reaction
Ligation-activated transcription
Lungs
Microbiology
NAA+probe
NAAT
NASBA
Nucleic acid sequence based analysis
P prime
PCR
PH
Point in time
Polymerase chain reaction
Probe amp
Probe with ampification
Probe with target amplification
Public Health
PublicHealth
QBR
QNT
Quan
Quant
Quantitative
Random
Ribonuclease
Ribonucleic acid
RS
SDA
Spec
Strand Displacement Amplification
TMA
Transcription mediated amplification

Copyright © 2023 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2023, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.

demo
request yours today
subscribe
start today
newsletter
free subscription

Thank you for choosing Find-A-Code, please Sign In to remove ads.