82388-0

LOINC Code


LOINC code82388-0
name
descriptionThis term was created for, but is not limited in use to, the submitter's test strip, a membrane strip pre-coated with a specific set of antigens in parallel lines. If antibodies to any of those antigens are present in the patient's serum, they will bind to the specific antigen. The bound patient antibodies are then detected using labelled anti-human antibodies. Various manufacturers classify this method as an immunoblot technique. LOINC uses the immunoblot (IB) method to mean that some electrophoretic/chromatographic separation occurs such that position (size) of the band is part of the assessment (as in Western blot). Because this assay does not involve a separation step but rather uses strips with pre-fixed antigens, the LOINC Method is Line blot.
statusACTIVE

Fully-Specified Name

component3-Hydroxy-3-Methylglutaryl-coenzyme A reductase Ab
propertyACnc  =  Arbitrary Concentration
timePt  =  Point in time:  To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements.
systemSer  =  Serum
scaleQn  =  Quantitative:  The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256
methodLine blot  =  Line blot:  A membrane strip pre-coated with a specific set of antigens in parallel lines that are incubated with antibodies in order to detect the targets of interest.

Additional Names

short name3-OH-3-Methylglutaryl-coA reductase Ab; ABS; Aby; Antby; Anti; Antibodies; Antibody; Arbitrary concentration; Autoantibodies; Autoantibody; HMGCR; Hydrox; III; NAM; Necrotizing autoimmune myopathy; OH; Point in time; QNT; Quan; Quant; Quantitative; Random

Basic Attributes

classSERO
type1  Laboratory
order vs. observationHMGCR Ab Ser Li
example UCUM unitsarb U/mL
The Unified Code for Units of Measure (UCUM) is a code system intended to include all units of measures being contemporarily used in international science, engineering, and business (www.unitsofmeasure.org)

History/Usage

first released
last updated2.68
last change typeMIN  - change to field other than name
change reason[arb'U]/mL

Related Names



Copyright © 2026 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2026, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.

demo
request yours today
subscribe
start today
newsletter
free subscription

Thank you for choosing Find-A-Code, please Sign In to remove ads.

Aimee - AI-powered coding assistant Would you like Aimee - AI
to help you with this?