85393-7
LOINC Code
| LOINC code | 85393-7 | ||||
|---|---|---|---|---|---|
| name | |||||
| description | Measuring the bone density of the humerus helps determine the best approach to treatment for patients being considered for shoulder surgery and those with humeral fractures. Patients needing shoulder surgery are at higher risk of local osteoporosis due to lack of mechanical stimulation, and general osteoporosis is a common risk factor for proximal humerus fractures in patients aged 65 and over. Determining the presence of osteoporosis pre-operatively can help decide if different repair techniques and hardware, such as threaded anchors, should be used. [PMID: 25027108] | ||||
| status | ACTIVE | ||||
Fully-Specified Name | |||||
| component | Views for bone density | ||||
| property | Zscore = Z Score | ||||
| time | Pt = Point in time: To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements. | ||||
| system | Upper extremity.left>Humerus | ||||
| scale | Qn = Quantitative: The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256 | ||||
| method | DXA | ||||
Additional Names | |||||
| short name | Arm; BMD; Bone Densiometry; Bone Density Scan; Den; Densiometry; DEX; DEXA; Dual Energy X Ray Absorptiometry; EXT; Extr-L; Films; Humerus-L; Imaging; L; LT; LUE; Point in time; QNT; Quan; Quant; Quantitative; Rad; RADIOLOGY; Random; Standard score; UE; UE | ||||
Basic Attributes | |||||
| class | RAD | ||||
| type | 2 Clinical | ||||
| order vs. observation | DXA Humerus-L Z | ||||
| formula (readable) | Z-score = (BMD - MEAN_BMD) / SD | ||||
| example UCUM units | Zscore The Unified Code for Units of Measure (UCUM) is a code system intended to include all units of measures being contemporarily used in international science, engineering, and business (www.unitsofmeasure.org) | ||||
Member of these Groups | |||||
| |||||
History/Usage | |||||
| first released | |||||
| last updated | 2.64 | ||||
| last change type | NAM - change to Analyte/Component | ||||
| change reason | {Zscore} | ||||
Related Names | |||||
Copyright © 2026 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2026, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.