PhenX - complete blood count protocol 220501   93340-8

LOINC Code


LOINC code93340-8
namePhenX - complete blood count protocol 220501
descriptionThe Complete Blood Count (CBC) protocol is a standard blood panel from the National Health and Nutrition Examination Survey (NHANES) and performed on participants aged 1 and older. Blood is collected from participants via standard venipuncture in a 3 or 4 ml K3 EDTA tube. The ambient blood sample is placed into a hematological analyzer for CBC and differential analyses. The blood should be tested as soon as possible after venipuncture and no later than 24 hours.
statusACTIVE

Fully-Specified Name

componentPhenX - complete blood count protocol 220501
property-
timePt  =  Point in time:  To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements.
system^Patient
scale-
methodPhenX

Additional Names

short namePhenX - CBC protocol

Basic Attributes

classPANEL.PHENX
type2  Clinical
order vs. observationBoth

Panel Components

66177-7History of Hemophilia
66178-5Cancer chemotherapy received in the past 4W or will be received in the next 4W
30525-0Age
8251-1Service comment
77301-0Reason care action performed or not
28570-0Procedure note
6690-2Leukocytes [#/volume] in Blood by Automated count
736-9Lymphocytes/100 leukocytes in Blood by Automated count
5905-5Monocytes/100 leukocytes in Blood by Automated count
770-8Neutrophils/100 leukocytes in Blood by Automated count
713-8Eosinophils/100 leukocytes in Blood by Automated count
706-2Basophils/100 leukocytes in Blood by Automated count
731-0Lymphocytes [#/volume] in Blood by Automated count
742-7Monocytes [#/volume] in Blood by Automated count
751-8Neutrophils [#/volume] in Blood by Automated count
711-2Eosinophils [#/volume] in Blood by Automated count
704-7Basophils [#/volume] in Blood by Automated count
789-8Erythrocytes [#/volume] in Blood by Automated count
718-7Hemoglobin [Mass/volume] in Blood
4544-3Hematocrit [Volume Fraction] of Blood by Automated count
787-2MCV [Entitic volume] by Automated count
785-6MCH [Entitic mass] by Automated count
786-4MCHC [Mass/volume] by Automated count
788-0Erythrocyte distribution width [Ratio] by Automated count
777-3Platelets [#/volume] in Blood by Automated count
32623-1Platelet mean volume [Entitic volume] in Blood by Automated count

Associated Observations

LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations.

History/Usage

first released
last updated2.67
last change typeADD  - added

Related Names

Pan
Panel
PANEL.PHENX
Panl
PhenX - CBC protocol
Pnl
Point in time
Random

Copyright © 2023 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2023, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.

demo
request yours today
subscribe
start today
newsletter
free subscription

Thank you for choosing Find-A-Code, please Sign In to remove ads.