95184-8

LOINC Code


LOINC code95184-8
name
descriptionThis panel contains results for Cytomegalovirus (CMV) CD8 T-Cell immune competence by Flow Cytometry. Patients tested are cytomegalovirus (CMV)-seropositive and may have 1 or more of the 5 major histocompatibility complex (MHC) alleles, including HLA A1, A2, B7, B8, or B35. Testing is performed to monitor CMV-specific CD8 T-cell responses in patients at higher risk of CMV disease. Testing may be performed on allo-hematopoietic stem cell or solid organ transplant patients who are at risk for developing late CMV disease or having CMV reactivation post transplant or after the cessation of antiviral prophylaxis. For transplant recipients and patients with autoimmune disorders receiving therapy with immunosuppressant agents, testing is useful for determining over immunosuppression within the CD8 T cell pathway. This panel was created for, but not limited in use to, Mayo's CMV CD8 T-Cell Immune Competence Quantitative Assessment by Flow Cytometry.[https://www.mayocliniclabs.com/test-catalog/Overview/88826]
statusACTIVE

Fully-Specified Name

componentCytomegalovirus T-cell immunodeficiency panel
property-
timePt  =  Point in time:  To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements.
systemBld  =  Whole blood
scaleQn  =  Quantitative:  The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256
methodFlow cytometry

Additional Names

short nameBlood; CELL MARKERS; CMV; CMV T-cell panel; Cytomegalo virus; Cytomgal; Dynamic; FC; HHV-5; Human Herpesvirus-5; Immunodeficiency Pnl; Pan; PANEL.CELLMARK; Panl; Pnl; Point in time; QNT; Quan; Quant; Quantitative; Random; T cell; T prime; UCHL-1; WB; Whol

Basic Attributes

classPANEL.CELLMARK
type1  Laboratory
order vs. observationCMV T-cell pane

History/Usage

first released
last updated2.68
last change typeADD  - added

Related Names



Copyright © 2026 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2026, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.

demo
request yours today
subscribe
start today
newsletter
free subscription

Thank you for choosing Find-A-Code, please Sign In to remove ads.

Aimee- AI -powered coding assistant - Try it now for Free Would you like Aimee - AI
to help you with this?