Gas panel - Arterial blood   24336-0

LOINC Code


LOINC code24336-0
nameGas panel - Arterial blood
descriptionKnowing the concentration of inspired O2 is important to the interpretation of PO2 results. Inspired O2 can be recorded in two ways- as percent- of O2 delivered to the patient (Venturi mask, re-breather mask, or ventilator) or as liters of oxygen per minute (nasal canula). This panel includes terms for recording the inspired O2 in either fashion. But because only one will apply and labs do not always receive this information they are designated as optional. The term "oxygen saturation" is often used to refer to two distinctly different quantities, hemoglobin oxygen saturation (recommended symbol = sO2) and fractional oxyhemoglobin (recommended symbol = FO2Hb). The former is sometimes called functional oxygen saturation and the later, fractional oxygen saturation Hemoglobin oxygen saturation = is the amount of oxyhemoglobin expressed as the percent of the hemoglobin able to bind oxygen, i.e. oxyhemoglobin (O2Hb) + deoxyhemoglobin (HHb). sO2 = 100 x O2Hb/ (O2Hb + HHb) Fractional oxyhemoglobin = the amount of oxyhemoglobin expressed as a percent of the total hemoglobin, where tHb = O2Hb + HHb + [COHb + MetHb + SulfHb]. Note that COHb, MetHb, and SulfHb, cannot carry oxygen and are thus called dyshemoglobins. FO2Hb = O2Hb/tHb Gas machines that can measure carbon monoxide, could, in principle, also report FO2Hb, and we had assumed that they would. However, at least some machines that do measure COHb and MetHb provide no option for reporting FO2Hb, and report only sO2. When mapping blood gas panels that report COHb% and also report FO2Hb, map that term to the LOINC term with the component of "Oxyhemoglobin /Total hemoglobin". If such an instrument reports only "oxygen saturation, verify with the lab that they are really reporting a functional O2 sat and not the Fractional Oxyhemoglobin, because the two are not always correctly labeled. If it is sO2 then map it to the LOINC term with a component of "Oxygen saturation". When you are mapping data from a simpler Blood gas instrument (one that can read fewer than 4 wave lengths), then the O2 saturation will likely be a sO2. So map also moat that variable to the LOINC with a component of "Oxygen Saturation". (Source: McD derived from Gill and McD- 2009 09)
statusACTIVE

Fully-Specified Name

componentGas panel
property-
timePt  =  Point in time:  To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements.
systemBldA  =  Blood arterial
scaleQn  =  Quantitative:  The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256
method

Additional Names

short nameGas Pnl BldA

Basic Attributes

classPANEL.CHEM
type1  Laboratory
order vs. observationOrder

Panel Components

2744-1pH of Arterial blood
33254-4pH of Arterial blood adjusted to patient's actual temperature
2019-8Carbon dioxide [Partial pressure] in Arterial blood
32771-8Carbon dioxide [Partial pressure] adjusted to patient's actual temperature in Arterial blood
2703-7Oxygen [Partial pressure] in Arterial blood
19255-9Oxygen [Partial pressure] adjusted to patient's actual temperature in Arterial blood
19218-7Oxygen content in Arterial blood
1960-4Bicarbonate [Moles/volume] in Arterial blood
2026-3Carbon dioxide, total [Moles/volume] in Arterial blood
1925-7Base excess in Arterial blood by calculation
1922-4Base deficit in Arterial blood
2708-6Oxygen saturation in Arterial blood
51733-4Oxygen saturation Calculated from oxygen partial pressure in Arterial blood
30313-1Hemoglobin [Mass/volume] in Arterial blood
3150-0Inhaled oxygen concentration
3151-8Inhaled oxygen flow rate
8310-5Body temperature

Associated Observations

LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations.

History/Usage

test rank668 of 2000 most commonly performed tests by labs in USA
order rank22 of 2000 most commonly ordered tests by labs in USA
first released
last updated2.73
last change typeMIN  - change to field other than name

Related Names

ABG
ART
Art bld
Art blood
Arterial
Arterial blood
BGas
Blood arterial
Blood gas
Blood gases
Chemistry
Gas Pnl
Gases
Pan
PANEL.CHEMISTRY
Panl
Pnl
Point in time
QNT
Quan
Quant
Quantitative
Random

Copyright © 2023 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2023, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.

demo
request yours today
subscribe
start today
newsletter
free subscription

Thank you for choosing Find-A-Code, please Sign In to remove ads.