Gas panel - Venous blood   24339-4

LOINC Code


LOINC code24339-4
nameGas panel - Venous blood
descriptionKnowing the concentration of inspired O2 is important to the interpretation of PO2 results. Inspired O2 can be recorded in two ways- as percent- of O2 delivered to the patient (Venturi mask, re-breather mask, or ventilator) or as liters of oxygen per minute (nasal canula). This panel includes terms for recording the inspired O2 in either fashion. But because only one will apply and labs do not always receive this information they are designated as optional. The term "oxygen saturation" is often used to refer to two distinctly different quantities, hemoglobin oxygen saturation (recommended symbol = sO2) and fractional oxyhemoglobin (recommended symbol = FO2Hb). The former is sometimes called functional oxygen saturation and the later, fractional oxygen saturation Hemoglobin oxygen saturation = is the amount of oxyhemoglobin expressed as the percent of the hemoglobin able to bind oxygen, i.e. oxyhemoglobin (O2Hb) + deoxyhemoglobin (HHb). sO2 = 100 x O2Hb/ (O2Hb + HHb) Fractional oxyhemoglobin = the amount of oxyhemoglobin expressed as a percent of the total hemoglobin, where tHb = O2Hb + HHb + [COHb + MetHb + SulfHb]. Note that COHb, MetHb, and SulfHb, cannot carry oxygen and are thus called dyshemoglobins. FO2Hb = O2Hb/tHb Gas machines that can measure carbon monoxide, could, in principle, also report FO2Hb, and we had assumed that they would. However, at least some machines that do measure COHb and MetHb provide no option for reporting FO2Hb, and report only sO2. When mapping blood gas panels that report COHb% and also report FO2Hb, map that term to the LOINC term with the component of "Oxyhemoglobin /Total hemoglobin". If such an instrument reports only "oxygen saturation, verify with the lab that they are really reporting a functional O2 sat and not the Fractional Oxyhemoglobin, because the two are not always correctly labeled. If it is sO2 then map it to the LOINC term with a component of "Oxygen saturation". When you are mapping data from a simpler Blood gas instrument (one that can read fewer than 4 wave lengths), then the O2 saturation will likely be a sO2. So map also moat that variable to the LOINC with a component of "Oxygen Saturation". (Source: McD derived from Gill and McD- 2009 09)
statusACTIVE

Fully-Specified Name

componentGas panel
property-
timePt  =  Point in time:  To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements.
systemBldV  =  Blood venous
scaleQn  =  Quantitative:  The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256
method

Additional Names

short nameGas Pnl BldV

Basic Attributes

classPANEL.CHEM
type1  Laboratory
order vs. observationOrder

Panel Components

2746-6pH of Venous blood
39486-6pH of Venous blood adjusted to patient's actual temperature
2021-4Carbon dioxide [Partial pressure] in Venous blood
40619-9Carbon dioxide [Partial pressure] adjusted to patient's actual temperature in Venous blood
2705-2Oxygen [Partial pressure] in Venous blood
19258-3Oxygen [Partial pressure] adjusted to patient's actual temperature in Venous blood
14627-4Bicarbonate [Moles/volume] in Venous blood
2027-1Carbon dioxide, total [Moles/volume] in Venous blood
1927-3Base excess in Venous blood by calculation
1924-0Base deficit in Venous blood
2711-0Oxygen saturation in Venous blood
51731-8Oxygen saturation Calculated from oxygen partial pressure in Venous blood
30350-3Hemoglobin [Mass/volume] in Venous blood
3150-0Inhaled oxygen concentration
3151-8Inhaled oxygen flow rate
8310-5Body temperature

Associated Observations

LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations.

History/Usage

test rank1039 of 2000 most commonly performed tests by labs in USA
first released
last updated2.73
last change typeMIN  - change to field other than name

Related Names

BGas
Bld ven
Bld venous
Blood - venous
Blood gas
Blood gas ven
Blood gases
Blood ven
Blood venus
Chemistry
Gas Pnl
Gases
Pan
PANEL.CHEMISTRY
Panl
Pnl
Point in time
QNT
Quan
Quant
Quantitative
Random
Venous

Copyright © 2023 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2023, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.

demo
request yours today
subscribe
start today
newsletter
free subscription

Thank you for choosing Find-A-Code, please Sign In to remove ads.