Platelet-derived growth factor receptor Ab [Presence] in Serum by Line blot 82432-6
LOINC Code
LOINC code | 82432-6 | ||
---|---|---|---|
name | Platelet-derived growth factor receptor Ab [Presence] in Serum by Line blot | ||
description | This term was created for, but is not limited in use to, the submitter's test strip, a membrane strip pre-coated with a specific set of antigens in parallel lines. If antibodies to any of those antigens are present in the patient's serum, they will bind to the specific antigen. The bound patient antibodies are then detected using labelled anti-human antibodies. Various manufacturers classify this method as an immunoblot technique. LOINC uses the immunoblot (IB) method to mean that some electrophoretic/chromatographic separation occurs such that position (size) of the band is part of the assessment (as in Western blot). Because this assay does not involve a separation step but rather uses strips with pre-fixed antigens, the LOINC Method is Line blot. | ||
status | ACTIVE | ||
Fully-Specified Name | |||
component | Platelet-derived growth factor receptor Ab | ||
property | PrThr = Present or threshold: The Property PrThr stands for “Presence or Threshold”, meaning either a) the actual presence or absence of an analyte, or b) that the amount of analyte detected is over some predetermined threshold. | ||
time | Pt = Point in time: To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements. | ||
system | Ser = Serum | ||
scale | Ord = Ordinal: Ordered categorical responses, e.g., 1+, 2+, 3+; positive, negative; reactive, indeterminate, nonreactive. | ||
method | Line blot = Line blot: A membrane strip pre-coated with a specific set of antigens in parallel lines that are incubated with antibodies in order to detect the targets of interest. | ||
Additional Names | |||
short name | PDGFR Ab Ser Ql Line blot | ||
Basic Attributes | |||
class | SERO | ||
type | 1 Laboratory | ||
order vs. observation | Both | ||
Associated Observations | |||
LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations. | |||
History/Usage | |||
first released | |||
last updated | 2.66 | ||
last change type | MIN - change to field other than name | ||
change reason | This term was created for an assay that uses a membrane strip pre-coated with a specific set of antigens in parallel lines. Because the antigens are seperated by electrophoresis/chromatographic separation during manufacturing, not during the test procedure itself, this test was assigned a LOINC Method of Immunoassay (IA) and not Immunoblot (IB). However, upon further review of IA, IB, and Immunoblot strip methodologies and regulatory distinctions between these, we changed the Method from IA to Line blot so that users can distinguish between these three Methods. The meaning of the term has not changed since it was created for an IB strip assay as described in the term description. | ||
Related Names | |||
|
Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.
Thank you for choosing Find-A-Code, please Sign In to remove ads.