Erythrocyte sedimentation rate by Photometric method   82477-1

LOINC Code


LOINC code82477-1
nameErythrocyte sedimentation rate by Photometric method
descriptionThis testing utilizes a photometric rheoscope methodology to measure the most critical phase of the early-phase in phenomenon of red cell sedimentation, rouleaux formation, to produce ESR results. Results are provided in 20 seconds, and the answers are extrapolated to mm/hr.
statusACTIVE

Fully-Specified Name

componentErythrocyte sedimentation rate
propertyVel  =  Velocity
timePt  =  Point in time:  To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements.
systemBld  =  Whole blood
scaleQn  =  Quantitative:  The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256
methodPhotometric

Additional Names

short nameESR Bld Qn Photometric

Basic Attributes

classHEM/BC
type1  Laboratory
order vs. observationBoth
example UCUM unitsmm/h
The Unified Code for Units of Measure (UCUM) is a code system intended to include all units of measures being contemporarily used in international science, engineering, and business (www.unitsofmeasure.org)
example unitmm/h

Associated Observations

LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations.

History/Usage

first released
last updated2.58
last change typeADD  - added

Related Names

Blood
Discocyte
E.S.R.
Erc
Erythrocytes
ESR
HEMATOLOGY/CELL COUNTS
Point in time
QNT
Quan
Quant
Quantitative
Random
RBC
Red blood cell
Red blood cells
Red blood corpuscle
Red blood corpusles
Red cell
Red cells
Sed rate
Velocity
WB
Whole blood

Copyright © 2023 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2023, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.

demo
request yours today
subscribe
start today
newsletter
free subscription

Thank you for choosing Find-A-Code, please Sign In to remove ads.