89579-7

LOINC Code


LOINC code89579-7
name
descriptionThe "high sensitivity" troponin assays manufactured by different vendors have different analytical characteristics, including the limit of detection and 99% upper reference limit (URL). The quantitative results from different assays should not be compared to make clinical decisions, and reporting the quantitative result in isolation is not recommended. The troponin high sensitivity quantitative results should be reported with information about the assay and/or the interpretation, depending on the specific reporting method used in a given laboratory or hospital, that are included in the High sensitivity Troponin I [LOINC: 89577-1] and Troponin T [LOINC: 89576-3] panels. 1. The laboratory device 99th percentile upper reference limit [LOINC: 89581-3] 2. The laboratory device coefficient of variation at 99th percentile URL [LOINC: 89580-5] 3. The laboratory device detection limit [LOINC: 87706-8] 4. Interpretation for troponin T [LOINC: 89575-5] and/or troponin I [LOINC: 89578-9] [PMID: 25204966]
statusACTIVE

Fully-Specified Name

componentTroponin I.cardiac
propertyMCnc  =  Mass Concentration
timePt  =  Point in time:  To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements.
systemSer/Plas
    Ser  =  Serum
    Plas  =  Plasma
scaleQn  =  Quantitative:  The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256
methodHigh sensitivity

Additional Names

short nameChemistry; cTnI; HS; Level; Mass concentration; Pl; Plasma; Plsm; Point in time; QNT; Quan; Quant; Quantitative; Random; SerP; SerPl; SerPlas; Serum; Serum or plasma; SR; TnI; TrI; Trop I; Troponin

Basic Attributes

classCHEM
type1  Laboratory
order vs. observationTroponin I SerP
example UCUM unitsng/L
The Unified Code for Units of Measure (UCUM) is a code system intended to include all units of measures being contemporarily used in international science, engineering, and business (www.unitsofmeasure.org)

Member of these Panels

89577-1

History/Usage

first released
last updated2.66
last change typeMIN  - change to field other than name
change reasonng/L

Related Names



Copyright © 2026 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2026, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.