94313-4
LOINC Code
| LOINC code | 94313-4 | |
|---|---|---|
| name | ||
| description | The quantitative cycle threshold value for the detection of nucleic acids within the N gene of the SARS-related Coronavirus (SARSr-CoV) in various specimens, including lower & upper respiratory, serum, stool or urine, by PCR with probe-based detection. This term was created for, but not limited in use to, the N3 primer-probe set used in the COVID-19 assay developed by the Centers for Disease Control and Prevention (CDC).[CDC: coronavirus/COVID-19/lab/] | |
| status | ACTIVE | |
Fully-Specified Name | ||
| component | SARS-related coronavirus N gene | |
| property | ThreshNum = Threshold Number | |
| time | Pt = Point in time: To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements. | |
| system | XXX | |
| scale | Qn = Quantitative: The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256 | |
| method | Probe.amp.tar.CDC primer-probe set N3 | |
Additional Names | ||
| short name | 3 Self-Sustaining Sequence Replication; 3SR SR; Amplif; Amplification; Amplified; Centers for Disease Control and Prevention; Corona virus; DNA NUCLEIC ACID PROBE; DNA probe; ID; Infectious Disease; InfectiousDisease; LAT; LCR; Ligase chain reaction; Liga | |
Basic Attributes | ||
| class | MICRO | |
| type | 1 Laboratory | |
| order vs. observation | SARS-related Co | |
| example UCUM units | Ct The Unified Code for Units of Measure (UCUM) is a code system intended to include all units of measures being contemporarily used in international science, engineering, and business (www.unitsofmeasure.org) | |
History/Usage | ||
| first released | ||
| last updated | 2.7 | |
| last change type | NAM - change to Analyte/Component | |
| change reason | {Ct_value} | |
Related Names | ||
Copyright © 2026 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2026, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.