Maximum clot strength amplitude [Length] in Blood by Thromboelastography.Tissue factor induced+platelet glycoprotein IIb-IIIa receptor inhibited   97015-2

LOINC Code


LOINC code97015-2
nameMaximum clot strength amplitude [Length] in Blood by Thromboelastography.Tissue factor induced+platelet glycoprotein IIb-IIIa receptor inhibited
descriptionThrombelastography determination of fibrin clot strength, stimulated by tissue factor, and platelets inhibited by a platelet glycoprotein IIb-IIIa receptor inhibitor such as abciximab. The maximum amplitude (MA) in TEG reflects both a plasmatic and platelet component. By including abciximab to inhibit binding of fibrin and fibrinogen to GPIIb/IIIa receptors, the platelet effect on MA is removed (at least partly), allowing more specific treatment of the patient. [PMID:14717978]
statusACTIVE

Fully-Specified Name

componentMaximum clot strength amplitude
propertyLen  =  Length
timePt  =  Point in time:  To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements.
systemBld  =  Whole blood
scaleQn  =  Quantitative:  The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256
methodThromboelastography.Tissue factor induced+platelet glycoprotein IIb-IIIa receptor inhibited

Additional Names

short nameMaximum clot strength amplitude Bld TEG.Tissue factor induced+platelet glycoprotein IIb-IIIa receptor inhibited

Basic Attributes

classCOAG
type1  Laboratory
order vs. observationObservation
example UCUM unitsmm
The Unified Code for Units of Measure (UCUM) is a code system intended to include all units of measures being contemporarily used in international science, engineering, and business (www.unitsofmeasure.org)
example unitmm

Associated Observations

LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations.

History/Usage

first released
last updated2.82
last change typeNAM  - change to Analyte/Component

Related Names

Blood
COAGULATION
Fac
Fact
gG
Glycoprot
Glycoproteins
GP
Hematology
Heme
Length
Point in time
QNT
Quan
Quant
Quantitative
Random
Rec
Recept
Receptors
Recp
Recptr
TEG
TEG.tissue factor induced
Thrombelastography
Thrombelastometry
Thrombocyte
Thrombocytes
WB
Whole blood

Copyright © 2025 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2025, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.

demo
request yours today
subscribe
start today
newsletter