85820-9
LOINC Code
| LOINC code | 85820-9 | ||
|---|---|---|---|
| name | |||
| description | In this assay, the reduction of clot firmness (i.e., clot lysis), is measured 30 minutes after maximum clot amplitude is reached. Heparinase is added prior to starting the assay in order to eliminate interference by any heparin that is in the patient's sample. | ||
| status | ACTIVE | ||
Fully-Specified Name | |||
| component | Clot firmness reduction^30M after maximum clot amplitude after addition of heparinase 30M = 30 minutes post challenge | ||
| property | LenFr = Length Fraction | ||
| time | Pt = Point in time: To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements. | ||
| system | Bld = Whole blood | ||
| scale | Qn = Quantitative: The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256 | ||
| method | Thromboelastography | ||
Additional Names | |||
| short name | 30M p MA p hep; add heparinase; Blood; CF; CF reduc; COAGULATION; Hematology; Heme; Length Fraction; P Hpase; Percent; Point in time; QNT; Quan; Quant; Quantitative; Random; TEG; Thrombelastography; Thrombelastometry; WB; Whole blood | ||
Basic Attributes | |||
| class | COAG | ||
| type | 1 Laboratory | ||
| order vs. observation | CF reduc 30M p | ||
| example UCUM units | % The Unified Code for Units of Measure (UCUM) is a code system intended to include all units of measures being contemporarily used in international science, engineering, and business (www.unitsofmeasure.org) | ||
Member of these Panels | |||
| |||
History/Usage | |||
| first released | |||
| last updated | 2.75 | ||
| last change type | MIN - change to field other than name | ||
| change reason | % | ||
Related Names | |||
Copyright © 2026 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2026, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.